docs.na.id.au

Overview

Ring Topology - Dual Switch Redundancy

Generated: 2026-09-05
Source: MAC address tables from Aruba JL253A and Siemens Scalance XR326-2C

Overview

This documentation describes the ring redundancy topology between two edge switches:

SwitchModelManagement IPRole
LAN-SWAruba JL253A (2930F)192.168.28.240Primary edge switch
Siemens PoE SwitchScalance XR326-2C192.168.28.241Secondary edge switch

Physical Connection

                    ┌─────────────────┐
                    │   OpenWRT Router│
                    │ (Clacks)        │
                    └────────┬────────┘
          ┌──────────────────┼──────────────────┐
          │                  │                  │
    ┌─────▼─────┐    ┌───────▼───────┐  ┌──────▼──────┐
    │ Aruba JL253A│    │ Siemens XR   │  │ Other Devices│
    │ LAN-SW     │◄───►│ Scalance    │  │ (end stations)│
    └────────────┘    │ XR326-2C     │  └──────────────┘
                      └──────────────┘

Connection Paths

Primary Path (Suggested)

The primary path runs Router → Aruba Switch → Siemens Switch → End Devices.

  1. Aruba Port ext-e 0/25 connects to router/firewall via SFP+ uplink
  2. Aruba Port ext-e 0/26 connects to Siemens Port Ex0/26 (ring connection)
  3. All other devices connect directly to Aruba switch ports

Alternate Path (Ring Redundancy)

When the primary uplink fails, traffic routes through:

  1. Siemens Port Ex0/26Aruba Port ext-e 0/26
  2. Traffic continues via Aruba’s main uplink path
  3. MRP (Media Redundancy Protocol) handles failover automatically

MAC Address Analysis - Devices by VLAN and Access Path


Source Disclaimer